Industrial Pump Motors

Air | Flange Mount

Ideal for environments in which electricty is not an option. Engineered for chemical applications and flammable / combustible liquids.

Model NumberAir ConsumptionOutputlbs (kg)
SP-A4     80 CFM (37 l/sec) @ 100 psi (7 bar)2 hp (1,5 kw)12 (5,4)
SP-A6 130 CFM (65 l/sec) @ 100 psi (7 bar)4 hp (3,0 kw)24 (11,0)
SP-A8    170 CFM (80 l/sec) @ 100 psi (7 bar)5 hp (3,7 kw)26 (11.8)
image
Pumping of flammable or combustible liquids can generate a static electric discharge, causing fire or explosion resulting in injury or death. Read and understand operating instructions before starting this unit. Follow all federal, state and local safety codes including NFPA 30 - NFPA77. Prior to connecting to air supply, install bond and ground wires and check continuity of each wire. A meter reading of one ohm or less is required for safe liquid transfer. Use only approved metallic pump tube, explosion proof or air motor, metallic drum and receiving vessel when pumping flammables. Air motors are not recognized under any current Underwriter’s Laboratory listing program. Consult a qualified engineer for suitability for use in a hazardous area or on flammables.